Saturday, August 24, 2019

RFID Based Rotary Car Parking System

This paper deals with the manufacturing of a Prototype of Rotary Car Parking System using Sensors. Lack of space availability has always been a problem in urban areas and major cities and to add to it there are cars parked callously on the streets that further limit the space. In order to handle the issue of parking in busy places various types of vehicle parking systems are used worldwide Rotary Automated Car Parking System and many more. This thesis work is aimed to develop a scale down working model of a car parking system which will reduce the excess use of land space. This total prototype is powered by unipolar stepper motor. This model also uses a RFID Tag and Reader. When the car comes on the ramp the switch will be activated and the pallet comes to carry the vehicle. When the switch will be operated by the operator, sprockets starts to rotate and the new space will be adjusted for new vehicle. Planners, developers, architects are finding out solutions to tackle this problem of parking, so took this opportunity to bring this technology of an automated parking system which will reduce a lot of land space for parking purpose. By testing and analyzing the working model definitely get the view to develop the parking lots at difficult and busy commercial places. 

by Aye Aye Nyein | Ohnmar Win "RFID Based Rotary Car Parking System"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5, August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd27852.pdf 

Paper URL: https://www.ijtsrd.com/engineering/electronics-and-communication-engineering/27852/rfid-based-rotary-car-parking-system/aye-aye-nyein

call for paper Information Technology, international journal Communication Engineering, ugc approved journals for engineering

Friday, August 23, 2019

Speed Control System of Induction Motor by using Direct Torque Control Method used in Escalator

Escalator is useful and act in the important part to carry passengers to the targeted floors of building. Every escalator must be driven by its own motor and this motor speed must be controled. To drive escalator with a constant speed, direct torque control technique is used to drive three phase squirrel cage induction motor. In this paper, the development of speed control system for three phase squirrel cage induction motor using a direct torque control method is presented and simulation for proposed system is done with the help of MATLAB SIMULINK. 

by Soe Sandar Aung | Thet Naing Htun "Speed Control System of Induction Motor by using Direct Torque Control Method used in Escalator"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5, August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd27903.pdf 

Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/27903/speed-control-system-of-induction-motor-by-using-direct-torque-control-method-used-in-escalator/soe-sandar-aung

call for paper Industrial Engineering, international journal Nuclear Engineering, ugc approved journals for engineering

Analysis of Three Phase Transformer Parallel Operation and Circulating Current

Parallel operation of transformers is needed when the load is increased and it exceeds the capacity of the existing transformer, if multiple transformers are running in parallel and a fault occurs in one transformer, then the other parallel transformers still continue to serve the load. The reliability is increased with parallel operation than to have a single larger unit. The cost associated with maintaining the spares is less when two transformers are connected in parallel. For parallel connection of transformers, primary windings are connected source bus bars and secondary windings are connected to the load bus bars. The conditions of connecting transformers in parallel and loading considerations when turn ratios, impedances and MVA ratings are different. Load division or load sharing store excess electrical power during low demand periods for release as demand rises. The goal would be for the power supply system to see a load factor of 1. In this thesis, two 100MVA transformers are connected in parallel. The 230 kV to 33 kV in Substation is used as the location to study and analyze the load division and circulating current of parallel transformer operation. The parallel operation provides more reliability. So, it is used in a substation. The value of the load division and circulating current are calculated with the case of the parallel transformer in this paper. 

by Zin Wah Aung "Analysis of Three Phase Transformer Parallel Operation and Circulating Current"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd26593.pdf 

Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/26593/analysis-of-three-phase-transformer-parallel-operation-and-circulating-current/zin-wah-aung

call for paper Transport engineering, international journal Software Engineering, ugc approved journals for engineering

Analysis of on Load Tap Changing Transformer for Substation

On load tap changing transformers play important roles in any modern power system since they allow voltages to be maintained at desired levels despite load changes. Traditionally, on load tap changer is a complex mechanical device, which has some deficiencies. On load tap changer of a transformer is presented, which can eliminate excessive conduction losses and suppress the arcing in the diverter switch, which is inherent in traditional on load transformer tap changers. The OLTC provides uninterrupted voltage is regulation of transformers under load. The transformer is equipped with a tapped winding whose tappings are connected with the tap selector of the OLTC. Most of the current commercially available automatic voltage regulators, just measure the low voltage side of the power transformer in order to control OLTC position. In this to improve tap changer control in order to perform properly also during a stressed situation in the 230 33 kV regulating power transformer for the substation. 

by Zin Wah Aung | Aung Thike "Analysis of on Load Tap Changing Transformer for Substation"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd26556.pdf

Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/26556/analysis-of-on-load-tap-changing-transformer-for-substation/zin-wah-aung

call for paper Information Technology, international journal Communication Engineering, ugc approved journals for engineering

Implementation of Automatic Door Opening System with Entry Counter for University Library

Automation is the technology by which a procedure or process is performed with minimal human assistance. This paper presents the implementation of automatic door opening system with entry counter for university library. It can be used not only for automatic door opening but also for counting entry person. It consists of entry unit and exit unit. Each unit consists of Arduino Uno, PIR Passive Infrared sensor and LCD Liquid Crystal Display . In entry unit, seven segment display is used as an entry counter to show the number of entry person. Welcome message and door condition are displayed on LCD. In exit unit, RTC Real Time Clock module shows a format of date and time on LCD. Quotes about library are also displayed on LCD. 

by Thae Hsu Thoung | Dr. Zin Ma Ma Myo "Implementation of Automatic Door Opening System with Entry Counter for University Library"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd26649.pdf 

Paper URL: https://www.ijtsrd.com/engineering/electronics-and-communication-engineering/26649/implementation-of-automatic-door-opening-system-with-entry-counter-for-university-library/thae-hsu-thoung

call for paper Chassis Engineering, international journal Electrical Engineering, ugc approved journals for engineering

Food Adulteration Its Implications and Control Approaches in India

In this modern era of globalization India is growing rapidly in almost all the areas but at the same time one of the most important issues which need more attention is food safety, because food adulteration has become a major problem of our society. This research work is an attempt to study different types of food adulteration such as unintentional, metallic contaminant and incidental, its reasons, health hazards and its control measures. To adulterate food items toxic substance are added to gain profit like Metanil yellow non permitted artificial colour is used to intensify the colour of turmeric powder, chalk powder and brick powder in chili powder but its health implications can lead anaemia, paralysis, brain damage, stomach disorder and cancer also. The bacterial and fungal contaminated cereal, dairy products, fermented foods have been reported to cause certain food borne illness and spoilage. As a solution consistency between domestic and international food policy measures without reducing safeguards to public health and consumer protection is the demand of time. The control approaches in India can lead with the help of government authorities, industries, scientific community and awareness of consumers. Beside this school education, research and development, industry and government regulatory authorities can also play a vital role. 

by Dr. Shashikant Pardeshi "Food Adulteration: Its Implications and Control Approaches in India"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd26514.pdf 

Paper URL: https://www.ijtsrd.com/engineering/food-engineering/26514/food-adulteration-its-implications-and-control-approaches-in-india/dr-shashikant-pardeshi

call for paper Telecommunications, international journal Information Technology, ugc approved journals for engineering

A Review of Transformer Winding Hot Spot Temperature

Adding weight, quantity power to try and do of power transformers is restricted principally by winding temperature As a part of bill of exchange tests on new units, the temperature go higher take a look at is advance to place examples on read of that, at full quantity and rated all spherical temperature the mean winding temperature wont be larger than the bounds cluster by trade quality examples. but the temperature of the winding isnt military dress and also the true limiting cause is really the foremost filled with heat a part of the winding normally referred to as winding burning style place. This burning style place half is placed some where toward the highest of the electrical device and not without delay have to be compelled to for straight to mensuration with common ways. The temperature of solid substance to stay things heat or cold is that the main explanation for electrical device obtaining previous. With temperature and time, the polysaccharide substance to stay things heat or cold undergoes a depolymerization method. because the polysaccharide chain gets shorter, the machine like properties of paper like stretching power and power to be elastic offer lower, smaller position to. within the finish the paper becomes without delay broken and isnt in a position of withstanding short approach taken by current forces and even traditional shaking that area unit a part of electrical device living. This place, position provides account of qualities the top of living of the solid substance to stay things heat or cold. Since its ineffectual to alter back, it additionally makes sure, clear the electrical device finish of life. This method is well veteran to electrical device homeowners and undergone efforts are created to pc viewing output the burning style place temperature to require additional probabilities of a touch cold all spherical temperature stretch the electrical device living whereas getting ready straight away facilitate required over weighting powers and takeng advantage of market probabilities. variety in sign one shows the sensitivity of paper to temperature current day transformers build use of thermally created sensible paper that has been with chemicals gave attention to urge well the while not modification, unmoving of polysaccharide structure. The rated heat place temperature for this sort of paper is 110c and it may be seen that a rise of 7c can just like the obtaining previous acceleration acted for owner. For older electrical device created with traditional wrapping paper, the rated heat place temperature is either 95c in line with ieee or 97c in line with IEC. This paper is additionally terribly sensitive to temperature and if of straight away facilitate required taking to be true a burning style place temperature of 140c the obtaining previous acceleration acted for owner is regarding one hundred, which suggests one hour during this condition is adequate one hundred hours at the rated temperature. Wet transformers solid substance to stay things heat or cold viewing over two water whats in cause AN addition of danger once operative at heat its been created clear that the left over water got by tricking in paper might get stretched to effervescent conditions and getting away from paper underneath the shape of vapour liquid balls with air within. 

by Rajiv Goyal | Neeraj Kumar | Rakesk Kumar "A Review of Transformer Winding Hot Spot Temperature"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5, August 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd24023.pdf 

Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/24023/a-review-of-transformer-winding-hot-spot-temperature/rajiv-goyal

call for paper Biomedical Engineering, international journal Civil Engineering, ugc approved journals for engineering